MAX-1 |
Replacement For:
- Analytical Industires [PSR-11-915]
- GE (Datex-Ohmeda) [0237-2034-700 Excel Modulus, 4700 Oxicap, 5250 RGM, 5120/5125 Monitor, 7800]
- HP [15201A]
- Hudson RCI [See Teleflex Medical]
- Mercury Medical [10-103-07]
- Pacifitech [PT-10]
- Teledyne [R15/#C-41131]
- Teleflex Medical (Hudson RCI) [5556]
- VTI [101272, 100352]
|
 |
MAX-2 |
Replacement For:
- Analytical Industires [PSR-11-915-1]
- Drager [Narkomed Series, Fabius GS, Fabius, GS, Tiro, 6850645, 6803290]
- HP [15201A]
- Invivo[Magnitude]
- Mercury Medical [10-103-12]
- Pacifitech [PT-24]
- Teledyne [R31]
- VTI [101372]
|
 |
MAX-3 |
Replacement For:
- City Technology [MOX-3]
- Paragon Platinum SC430
- Penlon [Prima SP2]
|
|

|
MAX-7 |
Replacement For:
- City Technology [MOX-4]
- EnviteC [00M-105]
- International Technologies [M-07]
- Teledyne [AX/MX300 Series, R17MED/#C-43690]
|
 |
MAX-8 |
Replacement For:
- Analytical Industires [PSR-11-915-3]
- GE (Datex-Ohmeda)[0237-2034-700, Excel Modulus, 5250 (ext. only), 5120/5125]
- Mercury Medical [10-103-13]
- Teledyne [R32MED/#B-73463]
- VTI [101272]
|
 |
MAX-9 |
Replacement For:
- Airshields [see Hillrom]
- Analytical Industries [PSR-11-55]
- Hillrom (Airshields) [6736140]
- Hudson RCI [See Teleflex Medical]
- Mercury Medical [10-103-03]
- Pacifitech [PT-05]
- Teledyne [R13, #B-39636]
- Teleflex Medical (Hudson RCI) [5500, V-05, 5590, 5577, 5584, 5595, 6477]
|
 |
MAX-10 |
Replacement For:
- Analytical Industries [PSR-11-915-4]
- City Technology [MOX-7]
- EnviteC [OOM-110]
- GE (Datex-Ohmeda)[6050-0004-110, Modulus SE, 7900 Series, Aisys, Aestiva Series, SmartVent S-5, Aespire]
- International Technologies [M-10]
- Mercury Medical [10-103-10]
- Pacifitech [PT-20A]
- Teledyne [R30MED/#B-72939]
|
 |
MAX-11 |
Replacement For:
- Airshields [See Hillrom]
- City Technology [MOX-16]
- Dräger [Narkomed, Fabius GS, Fabius Series, Babylog, Evita Family, 6850645, 6803290, Cato I 8000]
- EnviteC [OOM-201]
- Hillrom (Airshields) [PSR-11-915-2]
- Hudson RCI [See Teleflex Medical]
- International Technologies [M-02]
- Invivo [Magnitude]
- Mercury Medical [10-103-07]
- Pacifitech [PT-14A]
- Teledyne [R23, #C-61139]
- Teleflex Medical (Hudson RCI) [5557, V-14]
- VTI [101372, 100352]
|
 |
MAX-11i |
Replacement For:
- Drager Incubators [I8000 high temp. applications]
|
 |
MAX-12 |
Replacement For:
- Analytical Industries [PSR-11-917-M]
- City Technology [MOX-9]
- Datascope [Multinex Analyer, 0600-00-0002 (use Max-12f)]
- EnviteC [OOM-202]
- Hamilton [396008, 396009, Galileo, Raphael, Arabella, Aladdin, 51254, G5]
- Hudson RCI [See Teleflex Medical]
- IMT [PF300]
- International Technologies [M-04]
- Mercury Medical [10-103-06]
- MSA [472062, 470644]
- Pacifitech[PT-12A]
- Siemens [9004979-E347E]
- Spacelabs [90513, Capnograph]
- Teledyne [R24MED, #B-62321]
- Teleflex Medical (Hudson RCI) [5556, V-12]
- VTI [103100]
|
 |
MAX-12A |
Replacement For:
- Hillrom (Airshields) [Isolette Incubator]
- Viasys [Avea Ventilator, Sipap]
|
 |
MAX-13 |
Replacement For:
- Airshields [See Hillrom]
- Analytical Industries [PSR-11-917-J]
- Bio-Med Devices [10006 Sensor, M-10, M-2 Monitors, Sensor #4433, Monochrome Crossvent (use Max-13c)]
- City Technoligies [MOX-2]
- Covidien (Puritan-Bennett) [4-020933-00, 7820 Monitor, 7200 Vent]
- Datascope [Anestar S]
- EnviteC [OOM-102-1]
- Hillrom (Airshields) [6735142]
- Hudson RCI [See Teleflex Medical]
- Invivo [9445 Sensor]
- Mercury Medical [10-103-05]
- MSA [406931, MiniOX I, II, III, 3000]
- Pacifitech [PT-11A]
- Phillips (Respironics) [Criterion Vent, Espirit Vent Lifecare (#PLV-102), 37-079 Sensor]
- Precision Medical [PM5900, #504877]
- Puritan-Bennett [See Covidien]
- Teledyne [R17MED, #C-43690 (see Max-7 for AX/MX300 replacement]
- Teleflex Medical [5567, V-11]
- Viasys [66030 Sensor, 6400 Vent, 8400 Vent, VIP Vent]
- VTI [100580]
|
 |
MAX-13-250 |
Replacement For:
- Airshields [See Hillrom]
- Analytical Industries [PSR-11-917-J]
- Bio-Med Devices [10006 Sensor, M-10, M-2 Monitors, Sensor #4433, Monochrome Crossvent (use Max-13c)]
- Covidien (Puritan-Bennett) [4-020933-00, 7820 Monitor, 7200 Vent]
- Datascope [Anestar S]
- Hillrom (Airshields) [6735142]
- Hudson RCI [See Teleflex Medical]
- Invivo [9445 Sensor]
- Mercury Medical [10-103-05]
- MSA [406931, MiniOX I, II, III, 3000]
- Pacifitech [PT-11A]
- Phillips (Respironics) [Criterion Vent, Espirit Vent Lifecare (#PLV-102), 37-079 Sensor]
- Puritan-Bennett [see Covidien]
- Teledyne [R17, #C-43690]
- Teleflex Medical [5567]
- Viasys [66030 Sensor, 6400 Vent, 8400 Vent, VIP Vent]
- VTI [100580]
|
 |
MAX-14 |
Replacement For:
- Devilbiss [02ANA-101 Sensor]
- Mercury Medical [10-103-13]
- MSA [806572, MiniOx 1A]
- Pacifitech [PT-26]
|
|

|
MAX-16 |
Replacement For:
- Covidien (Puritan-Bennett) [4-072214-00, 840, 740, 760 & PB2000 Tester Vents]
|
 |
MAX-16HT |
Replacement For:
|
 |
MAX-17 |
Replacement For:
- Analytical Industries [PSR-11-77]
- Hudson RCI [See Teleflex Medical]
- Mercury Medical [10-103-02]
- Pacifitech [PT-03]
- Penlon [MTS]
- Teledyne [T-7]
- Teleflex Medical [5558, V-03]
|
 |
MAX-18 |
Replacement For:
- Analytical Industries [PSR-11-33-1]
- Hudson RCI [See Teleflex Medical]
- Mercury Medical [10-103-01]
- Pacifitech [PT-02]
- Teledyne [C1R, #B-39022]
- Teleflex Medical [5569, V-02, 5525, 5528, 5529, 5550, 5552]
|
 |
MAX-19 |
Replacement For:
- Analytical Industries [PSR-11-33-1]
- Hamilton [HM-01, Veolar, Amadeus, Arabella]
- Hudson RCI [See Teleflex Medical]
- Mercury Medical [10-103-00]
- Pacifitech [PT-01]
- Teledyne [T1 #A-37016]
- Teleflex Medical [5568 C1, C-01]
|
 |
MAX-21i |
Replacement For:
- Analytical Industries [PSR-11-233]
- Teledyne [B3C]
|
 |
MAX-23 |
Replacement For:
- City Technologies [MOX-1]
- Criticare [Poet IQ 8500, IQ2 8500Q, CAT644 Sensor]
- EnviteC [OOM-102]
- Teledyne [R22, #C-44611]
|
 |
MAX-41i |
Replacement For:
- Analytical Industries [PSR-12-233]
- Teledyne [B2C]
|
|

|
MAX-43 |
Replacement For:
- GE (Datex-Ohmeda) [Giraffe]
|
|

|
MAX-47 |
Replacement For:
- Teleflex Medical (Hudson RCI) [5800 Monitor, 5801 Analyzer, 5803 Sensor]
|
|

|
MAX-250 |
Replacement For:
- Maxtec [OM-25A]
- Mercury Medical [10-103-11]
- Pacifitech [PT-250]
- Teledyne [R29]
|
|

|
MAX-250E |
Replacement For:
- Maxtec [MaxO2+AE, OM-25AE, OM-25ME, MaxBlend, MaxVenturi]
- Analytical Industries [PSR-11-917-J1]
- CareFusion (Cardinal, Viasys) [Sentry Blender]
- Fluke [VT Mobile]
- Mercury Medical [10-103-08]
- Newport Medical [e360 & e500 vents]
- Pacifitech [PT-25A]
- Teledyne [R29MED/#C-70592]
- Viasys [Sentry Blender, 66045]
|
|

|
MAX-250ESF |
Replacement For:
- Maxtec [MaxO2+AE, OM-25AE, OM-25ME, MaxBlend, MaxVenturi]
|
|

|
MAX-250+ |
Replacement For:
|
|

|
MAX-250M |
Replacement For:
- Custom applications with Molex connector
|
|

|
SpiroQuant A+ |
Replacement For:
- Dräger [Narkomed, Fabius GS, Fabius, 6400, Babylog, Savina, Evita Family, Spirolog Sensor 8403735]
|
|

|
SpiroQuant H |
Replacement For:
- Hamilton [H72 VR-1, Galileo, Amadeus, Arabella, Aladdin Veolar, Raphael, Sensor H7400 AccuTach, 51254, 396008]
|
|

|
6850645 |
Dräger Oxygen Sensor
|
|
|
|
|
|
|
Download Reference Chart
|
 |
|
|
|
|
|
|
|
|
|
|
|